Compartilhamento |
|
Use este identificador para citar ou linkar para este item:
https://deposita.ibict.br/handle/deposita/230
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.contributor.author | FERREIRA, Ana Paula | - |
dc.contributor.authorLattes | http://lattes.cnpq.br/8834235691544808 | por |
dc.contributor.advisor | FERREIRA, Arthur | - |
dc.date.accessioned | 2021-05-10T18:32:37Z | - |
dc.date.issued | 2020 | por |
dc.identifier.uri | https://deposita.ibict.br/handle/deposita/230 | - |
dc.description.resumo | A acurácia dos métodos palpatórios tem sido abordada por estudos de validade que comparam seus resultados com um padrão de referência de imagem. Contudo, muitos métodos palpatórios ainda necessitam de análise de validade e/ou de confiabilidade. Atualmente não há evidências sobre a maioria dos métodos palpatórios da coluna cervical, além disso, não existe consenso sobre a influência dos dados pessoais e antropométricos sobre suas validades. O objetivo deste estudo é examinar a acurácia dos métodos palpatórios para a localização do processo transverso da primeira vértebra cervical (PTC1) e dos músculos masseter utilizando imagens radiológicas como método padrão ouro, e a associação entre as características pessoais e a acurácia observada. Métodos: Estudo de acurácia diagnóstica, simples cego. Noventa e cinco indivíduos (49 mulheres, 58 ± 16 anos) participaram do estudo. Um único examinador realizou testes palpatórios na região do pescoço e face de todos os participantes para identificar o PTC1 e o músculo masseter, bilateralmente. Em seguida, os participantes foram submetidos ao exame de tomografia computadorizada (TC) multi-slice para avaliação da estrutura corporal identificada. Dois radiologistas, cegados, um em relação ao outro e em relação a referência anatômica sob investigação, avaliaram as imagens da TC utilizando o mesmo critério. A acurácia palpatória foi calculada como a proporção das estruturas corporais identificadas corretamente na amostra estudada. A correlação dos resultados da palpação (correto = 1) e idade, sexo (masculino = 1) e o índice de massa corporal foi investigado utilizando-se o coeficiente de correlação ponto- biserial de Pearson. Resultados: Os processos transversos direito e esquerdo foram localizados corretamente em 76 (80%, IC 95% 71-87) e 81 (85%, IC 95% 77- 91) dos participantes, respectivamente, e bilateralmente em 157 eventos palpatórios (83%, IC 95% 77-87) avaliados por concordância dos dois radiologistas. Os músculos masseteres foram localizados corretamente em 100% dos participantes. Todas as variáveis demográficas apresentaram estimativas pontuais de correlação fracas ou inferiores com a acurácia da localização do TPC1; apenas a massa corporal foi correlacionada positivamente com a localização correta de TPC1 a direita (0,219, IC 95% 0,018 a 0,403, p = 0,033), determinando ~ 5% da variabilidade da acurácia. Conclusão: A acurácia da localização dos processos transversos da primeira vértebra cervical e músculos masseteres é alta. | por |
dc.description.abstract | The accuracy of palpation methods has been addressed by validity studies that compared their results with an imaging reference standard. Notwithstanding, many palpation methods still lack such validity and/or reliability analysis. Today, there is no evidence about the reliability and validity of most palpatory tests for the cervical spine. In addition, there is no consensus about the influence of personal and anthropometric data in their validity. This study aimed to examine the accuracy of palpation methods for locating the transverse processes of C1 (C1TP) and masseter muscle using radiologic images as the gold-standard method and the association between personal characteristics with the observed accuracy. Methods: Single-blinded, diagnostic accuracy study. Ninety-five participants (49 women, 58 ± 16 years of age) were enrolled in this study. A single examiner palpated the neck and face region of all participants to identify the C1TP and masseter muscles bilaterally. In sequence, participants underwent a multi-slice CT scan for assessment of the superimposed inner body structure. Two radiologists assessed the CT images using the same criteria and were both blinded regarding each other’s assessment and the anatomical landmarks under investigation. The palpation accuracy was calculated as the proportion of the correctly identified landmarks in the studied sample. The correlation of the palpation outcome (correct=1; incorrect=0) with age, sex (male=1; female=0), and body mass index was investigated using the point-biserial correlation coefficient. Results: The right and left transverse processes were correctly located in 76 (80%, IC 95% 71-87) and 81 (85%, IC 95% 77-91 of the participants, respectively, and bilaterally in 157 events (83%, IC 95% 77-87) as evaluated by the agreement of the two radiologists. The masseter muscles were correctly localized bilaterally in 95/95 (100%) of the participants. All demographic variables showed weak or lower point estimates of correlation with the accurate location of C1TP; only body mass was positively correlated to the correct location of C1TP at the right side (0.219, 95%CI 0.018 to 0.403, p = 0.033), determining ~5% of the variability of the accuracy. Conclusion: The accuracy of locating the C1 spinous processes and masseter muscles are high. | eng |
dc.description.provenance | Submitted by Arthur Ferreira (asferreira@unisuam.edu.br) on 2020-11-05T00:05:47Z No. of bitstreams: 1 2020 Tese Ana Paula Ferreira Antunes.pdf: 14594434 bytes, checksum: 947bd436ad82a68675957bd9ff18c84f (MD5) | eng |
dc.description.provenance | Approved for entry into archive by Lucas Paganine (lucaspaganine@ibict.br) on 2021-05-10T18:32:37Z (GMT) No. of bitstreams: 1 2020 Tese Ana Paula Ferreira Antunes.pdf: 14594434 bytes, checksum: 947bd436ad82a68675957bd9ff18c84f (MD5) | eng |
dc.description.provenance | Made available in DSpace on 2021-05-10T18:32:37Z (GMT). No. of bitstreams: 1 2020 Tese Ana Paula Ferreira Antunes.pdf: 14594434 bytes, checksum: 947bd436ad82a68675957bd9ff18c84f (MD5) Previous issue date: 2020 | eng |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior | por |
dc.format | application/pdf | * |
dc.language | por | por |
dc.publisher | Centro Universitário Augusto Motta | por |
dc.publisher.department | Centro Universitário Augusto Motta | por |
dc.publisher.country | Brasil | por |
dc.publisher.program | Programa de Pós-graduação em Ciências da Reabilitação | por |
dc.rights | openAccess | por |
dc.subject | Vértebras cervicais | por |
dc.subject | Atlas cervical | por |
dc.subject | Erros diagnósticos | por |
dc.subject | Palpação | por |
dc.subject | Exame físico | por |
dc.subject | Reabilitação | por |
dc.subject.cnpq | Fisioterapia e Terapia Ocupacional | por |
dc.title | Validade de métodos palpatórios para localização de estruturas das regiões massetérica e cervical por meio de imagens radiológicas de crânio e coluna cervical | por |
dc.type | Tese | por |
Aparece nas coleções: | Sudeste |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
2020 Tese Ana Paula Ferreira Antunes.pdf | Tese | 14,25 MB | Adobe PDF | Baixar/Abrir Pré-Visualizar |
Ferramentas do administrador